SETDSK_TXT extracted from UPDATE on 31 October 1994 Purpose: SETDSK is used to set the head step and tracks for the FLOPPY controllers. This command will work with the HFDC. Refer to the HFDC user's manual for proper switch setting. Usage: SETDSK [drive number][head step][tracks] [drive number] is from 1 to 4 and is valid ONLY for floppy only controllers. [head step] is from 0 to 3. Vary settings, "usually" 0 for optimal performance, but depends upon floppy type. [tracks] valid numbers are 4 or 8 to indicate 40 or 80 tracks respectively. Examples: SETDSK 104 sets drive 1, head step 0, 40 tracks SETDSK 228 sets drive 2, head step 2, 80 tracks SETDSK 308 sets drive 3, head step 0, 80 tracks Notes: Must leave only one space between command and options and you must not separate the numbers or error report will follow. WARNING--> SETDSK parameters are LOST after a WARM BOOT until re entered.